THERMAL POWER CALIBRATION OF NIGERIA RESEARCH REACTOR-1 BY CALORIMETRIC AND HEAT BALANCE METHODS

0
691

THERMAL POWER CALIBRATION OF NIGERIA RESEARCH REACTOR-1 BY CALORIMETRIC AND HEAT BALANCE METHODS

 

ABSTRACT
This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at two different power levels: half power (15kW) and full power (30kW). The calorimetric method involved operating the reactor at a constant power and isolating coiling system to avoid cooling of the pool water. For this method, the reactor pool temperature rise with time was measured, the reactor heat capacity constant was calculated and the heat losses from the reactor pool to the environment were evaluated. The power was then evaluated as a function of temperature-rise rate. The total thermal power is the sum of heat losses from the reactor pool to the environment and the power calculated as a function of temperature-rise rate. The heat balance method consisted of the steady state energy balance of the cooling loop of the reactor. For this method, the measurement of the inlet temperature, outlet temperature and temperature difference were carried out and also flow-rate of the coolant passing through the core was determined. The heat losses were evaluated and the values added to the power calculated as a function of flow rate and temperature difference gives the total thermal power. The Average water temperature rise during these experiments were: (29.5 to 32.0)oC and (27.0 to 29.6)oC for calibration at half and full power levels respectively .The thermal power obtained by the calorimetric method at half and full power were: (15.8±0.7) kW and (30.2±1.5) kW respectively. For heat balance method, the values of the thermal power obtained at half and full power were: (15.2±1.2) kW and (30.7±2.5) kW respectively. It was observed that the calorimetric method is more accurate with deviations of only 4% and 5% for calibrations at half and full power respectively. It is therefore recommended that the calorimetric method should be adopted for routine thermal power calibration of NIRR-1.

DOWNLOAD COMPLETE PROJECT MATERIAL

THERMAL POWER CALIBRATION OF NIGERIA RESEARCH REACTOR-1 BY CALORIMETRIC AND HEAT BALANCE METHODS

Leave a Reply